What is the fault of the outflow of KIA Sera heater pipeline?

The reason why the cold room often runs out of water:

1. The drain hole is blocked. After stopping the machine for defrosting, it should be thoroughly dredged with woven tape.

2. The door sealing strip is deformed and leaked, and needs to be replaced.

3. The door hinge is loose and displaced, and the door seal cannot be aligned with the door frame to close, resulting in air leakage. Reinstall the door hinge.

4. Cracking of the inner container of the cold storage room and deterioration of the performance of the insulation layer will cause serious freezing of the cold storage room and water running. Repairing the inner container, the performance of the insulation layer can not be repaired generally, except changing the box.

5. In the hot weather above 30 degrees, it exceeds the thermal insulation design capacity of the refrigerator. When the set temperature is low, the freezer will freeze badly and run out of water, but the weather is cool and natural.

6. Failure of other parts of the refrigeration system, such as thermostat failure, makes it difficult to stop the compressor. Moreover, serious freezing in the cold storage room will cause the cold storage room to run out of water, which needs careful inspection and troubleshooting.

I hope my answer can help you.