Office decoration pays attention to how to design office walkways.
In the daily decoration design, remember not to ignore the design of office corridors, but to take an important attitude. In the design process, we should focus on the number of safety exits, and design and decorate according to the fire protection code. Secondly, when you are in office decoration, you should make clear the location of the safety exit, and at the same time, you are not allowed to set up completely evacuated items.
In the design of office walkways, evacuation routes are also an important factor. Reasonable pedestrian walkways should be set up in large space office areas, and office decoration materials for corridor decoration design should be designed in full accordance with fire protection requirements.
Use fireproof materials. Office walkway decoration design, office building design in office decoration, what is the minimum distance from the walkway to the stairs? What is the minimum clear width of the office building walkway? Do office building walkways need emergency lighting? Corridor bears the connecting function of each space, and the design of corridor affects the utilization of the whole spatial pattern. At the same time, reasonable corridor design can greatly improve the utilization rate and aesthetic feeling of office space. This corridor decoration is not only a simple corridor function, but also adds corporate culture to the corridor design scheme, which allows customers to fully experience corporate culture in every corner of the office space.
1. Ensure the number and smoothness of safety exits.
In the decoration design of office walkways, the number and width of safety exits should meet the requirements of specifications. It should be strictly controlled that two or more units * * * use one level of large space for office work.
There should be a public walkway connecting two safety exits, and the masonry of the walkway wall should meet the requirements of the fire protection code. In office decoration, the original designed exit shall not be blocked, and desks, cabinets and stacked items that hinder safe evacuation shall not be set within 2m of the stairwell or the front door of the front room. 2. The setting of fire doors.
The setting of fire doors in the decoration design of office walkways should ensure that it does not affect the safe evacuation of personnel. When the fire door at the safety exit needs to be locked and closed for safety reasons, it shall meet one of the following requirements:
1) The door is equipped with an electromagnetic door lock linked with the fire alarm system. When the fire alarm detector detects a fire, it can open the door by cutting off power or sending electricity.
2) The inside of the door should be provided with a push latch, and the outside of the door should be provided with a fire lock (this kind of door lock should be consistent throughout the building, and its mother key should be kept by the fire control room.
3) The access control system adopted in the building, in case of fire,
The door is automatically or remotely opened by the control center of the building automation system (near the fire control room or in a large room). When the power is cut off, the fire door must be in an openable state. 3. Evacuation passage.
There should be a natural pedestrian passage in the large space office area, and the width of the passage should be calculated and determined according to the fire evacuation time and the number of people, and should not be less than 1.4m, and connected with the safety exit; The straight-line distance between the two exits of the large space office and the nearest evacuation exit should not exceed 30m, and the walking distance along the natural passage should not exceed 45m. The straight-line evacuation distance of one-way evacuation place should not exceed 12m, and the walking distance along the natural passage should not exceed 18m (when the straight-line included angle between any point in the room and the emergency exit is less than 450, it should be regarded as one-way evacuation).
4. Fire evacuation lighting system in office walkway decoration design.
Lighting exit signs should be installed above the exit. The spacing of evacuation signs should not be greater than 20m. Evacuation signs set on natural passages or walkways shall be installed on the wall or ground below 1.00m; Evacuation signs in large space office areas can be installed under the ceiling that can be seen by internal personnel.