Advantages and disadvantages of installing floor heating on balcony

Advantages and disadvantages of installing floor heating on balcony are as follows

First, interests.

Installing floor heating on the balcony can make residents feel all-round warmth in winter. Floor heating is laid on the balcony, which increases the insulation layer and can enhance the sound insulation effect.

Second, shortcomings.

1. Most balconies are used to hang clothes. There are too many detours in the floor heating pipeline, and there are more hidden dangers of siltation. At present, there is no absolutely effective dredging method, and only reasonable pipeline laying is considered to prevent it. Generally, the balcony is far away from the water separator, which is particularly unfavorable for pipeline dredging. Moreover, walking alone may not have enough water separators, which may have certain hidden dangers.

Compared with other rooms, the balcony is full of light. At present, the temperature of families with floor heating is generally high, and it is not suitable for frequent window opening when the temperature is low and windy in winter. If the balcony is covered with floor heating, there will be a relatively low temperature environment to provide fresh air, which will also increase the decoration cost.

Matters needing attention in using floor heating:

1, which will not be enabled in winter after system installation. If the indoor temperature is lower than 5℃, air compressor should be used to blow out all the water in the system to prevent the system from freezing.

2. The initial heating (debugging) should be carried out under the guidance of the company's technical personnel, and it is forbidden to put it into use without debugging.

3. The water supply temperature of the low-temperature hot water floor radiant heating system should be 35-50℃, not exceeding 60℃, and the working pressure of the heating system should not exceed 0.8MPa.

4. When the user starts the geothermal heating system every winter, it must be carried out step by step in strict accordance with the prescribed heating program cycle, and the temperature cannot be raised in one step.

5. Users can clean the filter at the front end of the water separator before use every year to ensure the cleanliness of the water pipe and prevent the pipe from being blocked. The specific method is as follows: first, close the inlet and outlet valves of the connecting conduit, then open the filter, take out the filter and clean it, and check whether the filter is damaged or blocked. If it is damaged, replace the filter screen with the same specification and install it as it is.

6. During the water supply or use of the floor heating system, air may accumulate in the pipeline, which will affect the heating effect. At this time, the air release valves of the water distributor and the water collector can be opened to discharge the gas, and the method is the same as that of traditional heating.