China Naming Network - Feng Shui knowledge< - What is the rated wind pressure and temperature of the power generation boiler in thermal power plant?

What is the rated wind pressure and temperature of the power generation boiler in thermal power plant?

The boilers in thermal power plants have different pressure grades and temperatures according to the unit size, which can be divided into low pressure, medium pressure, high pressure, ultra-high pressure, subcritical and supercritical units. \ r \ For low-pressure boilers with outlet steam pressure less than or equal to 2.45MPa, the steam temperature is mostly saturated or not higher than 400℃. \ r \ The outlet steam pressure of the medium-pressure boiler is 3.83MPa, and the steam temperature is 450℃. \ r \ The steam pressure at the outlet of ultra-high pressure boiler is set to 13.7MPa, and the steam outlet temperature is 540℃ or 555℃. \ r \ The outlet steam pressure of subcritical pressure boiler is specified as 16.7MPa, and the outlet steam temperature is 540℃ or 555℃, with a few being 570℃. \ r \ The pressure of supercritical boilers is mostly between 25-27MPa and 27MPa.