How high should a geothermal water distributor be hung?
There are no specific requirements for the installation of geothermal water distributors. The valve under the water collector should be at least 30cm from the floor. It can be installed horizontally without affecting the use or blocking the space.
The basic classification of geothermal water distributors is divided into three types in terms of function and structure: basic type, standard type and functional type.
Basic type: composed of water distribution main pipe and water collection main pipe. A ball valve is installed on each branch port of the main water distribution pipe, and a manual exhaust valve is installed on the main water distribution pipe. The basic water distributor does not have flow adjustment function.
Standard type: The structure of the standard type manifold is the same as the basic type, except that the ball valves on each main pipe are replaced by flow regulating valves. Replace the manual exhaust valves on the two main pipes with automatic exhaust valves. The standard water collector can precisely adjust the flow rate of each loop, and even the flow adjustment of the luxury standard water collector can realize artificial intelligence adjustment.
Functional type: In addition to all the functions of the standard water collector, the functional water manifold also has temperature and pressure display functions, automatic flow adjustment functions, automatic water mixing and heat exchange functions, Thermal energy metering function, indoor zone temperature automatic control function, wireless and remote control function. In order to prevent corrosion, the water collector is generally made of corrosion-resistant metal or synthetic materials.
Commonly used materials include copper, stainless steel, copper nickel plating, alloy nickel plating, high temperature resistant plastics, etc. The internal and external surfaces of the manifold (including connectors, etc.) should be smooth and clean, without cracks, blisters, cold insulation, slag inclusions, uneven unevenness. Connectors plated on the surface should have a uniform color, a solid coating, and no deplating. defects.
Extended information:
Tips for using geothermal water distributor:
First, the water distributor can control the water supply flow of each room or area in separate ways, such as : If any rotary core valve on the water distributor is closed halfway, the temperature of the room heated by this waterway will decrease.
Second, the manual exhaust valve on the water distributor. If there is poor heating or air blockage during heating in winter, the user can use the exhaust device to manually exhaust the air in the floor heating pipe. , ensure the normal circulation of hot water.
Third, there is a filter on the front end of the water distributor. During the annual heating period, the user regularly or irregularly removes the filter screen at the lower end of the filter, cleans it and then installs it to ensure the cleanliness of the water pipe. . After heating is completed, the pipe network should be flushed with clean water.
Fourth, if you are away from home for a long time, you can use the main valve of the water distributor to reduce the amount of circulating water. Never close it all. If the room is not heated throughout the winter, the water in the pipes should be blown out.