What are the internal issues that need to be paid attention to during factory decoration?
1. The first detail to pay attention to in factory decoration is to evaluate the ground, because the ground must be kept flat during factory decoration. If it is not flat, it will have a certain impact on the future factory. If there is Uneven areas should be paved immediately with 1:3 cement mortar or directly paved with self-flowing cement.
2. There is a certain relationship between the large wire trough and the ground. Be sure to pay attention to the width and depth of the wire trough. If the size is insufficient, the ground will be uneven after laying out the wire duct, resulting in reverse work later. .
3. If there are some new spaces in the indoor partition, according to the fire protection regulations, independent smoke detectors must be added, and a professional factory decoration company must be hired to do the fire protection. Usually the maintenance unit of the building will fail the property inspection if this detail and the second detail are not corrected.
4. In the factory decoration, the network wiring and all the wires that need to be passed through the pipe must be made of steel pipes, not the PUC pipes often mentioned at home. The wire boxes must also be made of iron (sometimes PUC can also be used) use).
5. After talking about the details of the ground, above the ground, there are also certain standards for fire protection in modern factory decoration. If the factory building needs a suspended ceiling, all the nozzles in the site must leak out of the suspended ceiling. A certain size and level.
6. Due to the relatively small scale of many factory decoration processes, special wiring companies are often not hired to modify weak points (including network cables and telephone lines). This requires special attention, data and The voice tags must be placed during the time period when the line is released, so as not to cause trouble in subsequent work.
7. Many factories are now equipped with central air conditioning and fresh air systems, but the indoor air outlets may not exactly meet the requirements. In this case, a professional decoration company needs to send professionals to extend or modify the air outlets, and ceilings are required. Cooperation from the Engineering Department.
8. Regardless of whether the factory ceiling is made of asbestos boards or mineral wool boards, it must be hung with Lowes tie rods so that it can be stable and durable for a long time. If it is hung with iron wires, it is absolutely not allowed. Office equipment comes into the site. In the future, strong and weak current wiring will need to be installed at each post along with the installation of office partitions to prevent random placement.